Showing results: 421 - 435 of 649 items found.
-
MSXB 078 -
Microstar Laboratories, Inc.
The Microstar Laboratories Isolated Digital Expansion Board, part number MSXB 078, provides isolated digital expansion for Data Acquisition Processor (DAP) systems. Use these boards to eliminate ground currents – a potential source of noise in your measurement and control signals – and eliminate timing errors from high-channel count digital I/O.
-
E5053A -
Keysight Technologies
The E5053A microwave downconverter is designed to operate with the E5052A/B signal source analyzer (SSA). When configured with the E5053A microwave downconverter, the E5052A/B SSA offers exceptional phase noise sensitivity up to 26.5 GHz. Additionally, combining a pair of 11970 series harmonic mixers offers the phase noise measurement up to 110 GHz.
-
Salicon Nano Technology
As Rigol's RF first signal source, the DSG3000 series offers standard AM/FM/ØM analog modulation, as well as options for I/Q modulation and I/Q baseband output. The instrument is available with maximum frequencies of either 3 GHz or 6 GHz. Featuring a high signal purity with phase noise measuring <-110dBc/Hz@20kHz (typical) and a wide output range of -130dBm to +13dBm, the DSG3000 RF signal generator has standard pulse modulation with an on/off ratio of up to 80dB, with optional pulse train generator available. The DSG3000 series also has an amplitude accuracy of <0.5dB (typical).
-
1U647-001 -
Sigma Tek, Inc.
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
6-Watt Blue Engraving Laser -
Advanced Photonic Sciences LLC
Can be used in laser engraving, marking, and cutting applications. Process wood, plastics, metals, anodized aluminum, stone, tile, and other materials. The adjustable spot can be adapted to the needed distance from laser to the material. The spot, with a size of <100 μm, creates very fine engravings and sharp cutting edges. The built-in driver accepts TTL and analog signals for power adjustments. The laser can be controlled between 0% and 100% of output power. It comes preset and needs only a power supply and a signal source.
-
Model 2313 -
ICS Electronics
* Provides 128 high-power TTL I/O lines that can sink 48 mA or source 24 mA. * Easily interfaces to TTL or CMOS signals and contact closures. * User can configure the data bytes as inputs or outputs.* Transfer data as bits, bytes as data strings or transparently.* Separate headers for RS-232 and RS-485 signals. * Optional 2313 Flat Ribbon Cables mount DE-9 male or female connectors on the rear panel. * Optional Relay Driver boards with 64 or 128 Relay Drivers.
-
40-522-021 -
Pickering Interfaces Ltd.
Medium density PXI dual 12x8, 1-pole matrix - it is also available inreed relayformats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable forswitching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems.The two banks may be used for operating a 4-wire measurement system (bank-1 for source,bank-2 for measure). Larger matrices may be constructed by daisy chaining the commonsignals from multiple PXI Modules.
-
E5505A -
Keysight Technologies
The Keysight Technologies E5500 Series of phase noise measurement solutions offers the most flexible set of measurements on one-port VCOs, DROs, crystal oscillators and synthesizers. Two-port devices, including amplifiers and converters, plus CW, pulsed and spurious signals can also be measured. The E5500 measurements include absolute and residual phase noises, AM noise, and low-level spurious signals. The stand-alone instrument architecture easily configures for various measurement techniques, including the PLL/reference source technique, residual and FM discriminator methods.
-
Model 4813 -
ICS Electronics
* Provides 128 high-power TTL I/O lines that can sink 48 mA or source 24 mA. * Easily interfaces to TTL or CMOS signals and contact closures. * User can configure the data bytes as inputs or outputs.* Transfer data as bits, bytes as data strings or transparently.* Optional Relay Driver boards add 64 or 128 Relay Drivers.
-
TLA7000 -
Tektronix, Inc.
The modular TLA7000 Logic Analyzer Series provides the speed and flexibility you need to capture logic detail on today's fastest microprocessors and memory designs. Pinpoint the source of elusive errors and gain the visibility you want with large easy-to-read displays, fast data throughput, and time-correlated views of analog and digital signals through the same probe.
-
MSXB 076 -
Microstar Laboratories, Inc.
The Microstar Laboratories Isolated 16-Bit Analog Output Board, part number MSXB 076, provides isolated analog outputs for Data Acquisition Processor (DAP) systems. Use these boards to eliminate ground currents – a potential source of noise in your measurement and control signals – as well as to eliminate phase errors from analog outputs in your application.
-
PDExpert -
Power Monitoring and Diagnostic Technology Ltd.
The PDExpert is PMDT's third level of Partial Discharge (PD) Expert Diagnostic and Location System. It is a powerful, portable, multi-channel system of impeccable design used to analyze and pinpoint PD signals coming from a power asset within centimeters while the power system is energized. The system consists of UHF, AE, HFCT and ultrasonic sensors, one advanced UHF/PD signal processing unit, one oscilloscope, filters and other accessories.The system employs ultra-high speed data acquisition and advanced digital signal processing technologies, compares the UHF, AE and HFCT signals of different frequency ranges to determine if it is PD or noise, and locates the source in power assets accurately by utilizing Acoustic-Electromagnetic Combination Location Technique, time Difference of Signals' Arrivals (TDOA), and 3D Positioning Technology.
-
Precise Time and Frequency, Inc.
The ptf 1230A(1U)/1231A(2U) GPS L-Band RF Distribution amplifiers provide high performance GPS signal references for laboratory or systems use. In most applications the low noise and signal gain capability of the units will provide userswith a robust GPS signal source for lab or system requirements.The ptf 1230A/1231A uses individually buffered output stages and insures maximum isolation between the individual outputs. The ptf 1231A offers 12 outputs. Options are available for a 2U/3.5” version (ptf 1230A) with 24 outputs.Isolation from output to output is >-40 dB. The input also offers DCV for biasing an active antenna.
-
HighFinesse GmbH
HighFinesse optical spectrometers LSA and HDSA are designed to analyse the multi-line or broadband spectrum of (un-)known light sources like cw and pulsed lasers, gas discharge lamps, super luminescence diodes, semiconductor laser diodes and LEDs. They are suitable to analyze the spectrum of telecom signals, resolve Fabry-Perot modes of a gain chip, and produce a spectral measurement of gas absorption.
-
F70PV -
FLC Electronics Inc
The F70PV is a very fast, unipolar, linear amplifier having a variable amplification of 0-10 times and capable of voltage output of +70V. Any functiongenerator or arbitrary waveform generatoror any othe signal source can be used as an input device. The amplifier's output is linear from DC up to ca 10 megahertz range. It can be used in a wide range of high speed applications.